The Valiant rehab is a modern designed treadmill for various ergometry purposes. It is a reliable treadmill that can be controlled both manually and by external equipment. The Valiant has a zero starting speed with a smooth acceleration from 0 km/h. It has a running surface of 170 x 60 cm, very suitable for taller patients
Maximum speed | 12 km/h | 7.5 mph | maximum speed of the treadmill |
Minimum operational speed | 0.1 km/h | 0.1 mph | minimum speed of the treadmill |
Positive elevation | 25 % | maximum positive angle as a percentage | |
Optional negative elevation | -10 % | mimimum negative angle percentage that can be reached with the optional accessory |
Allowed user weight | 160 kg | 352.7 lbs | maximum patient weight |
Readout Angle | Readout actual elevation on control unit (treadmill only) | ||
Readout Distance | Readout the distance on control unit | ||
Readout Speed | readout the actual speed on control unit | ||
Readout Heartrate | Readout the actual heartarte on control unit | ||
Readout Time | Readout time on control unit | ||
Manual operation mode | Operate manually | ||
Protocol operation mode | Possibility to program protocols with time, speed and elevation | ||
Quick start operation mode | Easy quick start possible | ||
Heartrate controlled protocols operation mode | Possibility to programm controlled protocols (only possible with HR option) | ||
Preset protocol operation mode | Operate via preset protocols | ||
Heartrate controlled operation mode | Only possible with HR option |
Lode ERM interface protocol | supports communication according to the Lode ERM treadmill protocol | ||
"HP Cosmos" interface protocol | supports communication according to the "HP Cosmos" protocol | ||
"Woodway" interface protocol | supports communication according to the "Woodway" protocol | ||
"Trackmaster" interface protocol | supports communication according to the "Trackmaster" protocol | ||
"GE" interface protocol | supports communication according to the "GE" protocol | ||
USB connector | connection via USB possible | ||
RS232 in connector | connection via RS232 |
Walking surface length | 170 cm | 66.9 inch | length of the walking surface |
Walking surface width | 60 cm | 23.6 inch | width of the walking surface |
Product length (cm) | 233 cm | 91.7 inch | length of product in cm |
Product width (cm) | 90 cm | 35.4 inch | width of the product in cm |
Product height | 135 cm | 53.1 inch | height of product |
Product weight | 149 kg | 328.5 lbs | the weight of the product |
115 V AC 50/60 Hz (138 VA) | operational power | ||
230 V AC 50/60 Hz (138 VA) | operational power | ||
Maximum motor power | 1.8 kW | the maximum power the motor will consume |
IEC 60601-1:2005 | the product is IEC 60601-1 3rd edition compliant | ||
ISO 13485:2016 compliant | Lode fulfils ISO 13485:2016 requirements | ||
ISO 9001:2015 compliant | Lode fulfills ISO 9001: 2015 requirements | ||
Standard emergency lanyard | an emergency stop with a magnetic lanyard is present |
Minimum operational temperature | 14 °C | minimum temperature at which the device will work within specification | |
Maximum operational temperature | 40 °C | maximum temperature at which the device will work within specification | |
Minimum operational air pressure | 70 kPa | minimum airpressure as from which the product will be operating within specification | |
Maximum operational air pressure | 106 kPa | maximum air pressure as from which the product will be operating within specification | |
Minimum operational non-condensing humidity | 90 % | minimum non-condensing humidity at which the product will operate within specification | |
Maximum operational non-condensing humidity | 90 % | maximum non-condensing humidity at which the product will operate within specification | |
Minimum storage & transport temperature | -25 °C | minimum temperature the product may be stored and transported at | |
Maximum storage & transport temperature | 70 °C | maximum temperature the product may be stored or transported at | |
Minimum air pressure storage & transport | 50 kPa | minimum air pressure the product may be stored or transported at | |
Maximum storage & transport air pressure | 106 kPa | maximum air pressure the product may be stored and transported at | |
Min. humidity storage & transport | 10 % | minimum non-condensing humidity that the product can be stored or transport at | |
Max. humidity storage & transport | 95 % | max. non-condensing humidity that the product can be stored or transported at |
Balke | Balke Treadmill protocol | ||
Bruce | Bruce Treadmill Protocol |