Lode Cardiac Rehab Manager 16

Turn key Cardiac Rehabilitation Management setup

With the LCRM a new modular system for controlled ergometer training is developed. The PC software takes over the entire predefined training control of the patients, documents all relevant data (e.g. ECG, heart rate, training data, etc.) at the same time and so relieves the therapist of routine work – the patients can be taken care of more intensively. Together with the Lode bicycle and treadmill ergometers the LCRM is ready for the future. Up till 16 ergometers can be controlled. The data of ergometers, test subjects and the ECG signal are combined in the software. This makes it possible to use the system in combination with ergometers, but also stand-alone (e.g. floor exercises). The ECG connection is wireless enabling the test subjects to move around freely. The software provides individual reports and continuous ECG control. Both group testing and individual testing is possible. The total solutions exists of the LCRM software, Lode ergometers and a wireless 2-lead ECG amplifier.

Specifications

60 Hertz Filter
60 Herz ECG Filter
50 Hertz Filter
50 Hertz ECG Filter
Two channel ECG monitoring
ECG monitoring with 4 leads, two channel
Alarm Heart Rate
Alarm Heart Rate
Alarm Blood Pressure
Alarm Blood Pressure
Audio Alarm
Audio Alarm
Remote Battery Indication
Remote Battery Indication
Versatile database connection
Versatile database connection
English user interface
User interface available in English language
Chinese user interface
User interface available in Chinese language
Czech user interface
User interface available in Czech language
Dutch user interface
User interface available in Dutch language
French user interface
User interface available in French language
German user interface
User interface available in German language
Italian user interface
User interface available in Italian language
Japanese user interface
User interface available in language
Korean user interface
User interface available in Korean language
Polish user interface
User interface available in Polish language
Russian user interface
User interface available in Russian language
Spanish user interface
User interface available in Spanish language
Turkish user interface
User interface available in Turkish language
Customized Screenviews
Customized Screenviews
Customized Reports
Customized Reports
Personalized Color Settings
Personalized Color Settings
Software available in English
Software available in English
Software available in German
Software available in German
Software available in Dutch
Software available in Dutch
Software available in French
Software available in French
Software available in Russian
Software available in Russian
Software available in Polish
Software available in Polish
Software available in Turkish
Software available in Turkish
Software available in Japanese
Software available in Japanese
RS232 connection to Lode ergometers
RS232 connection to Lode ergometers
USB connection to Lode treadmills
USB connection to Lode treadmills
Bluetooth available
connectivity through Bluetooth available
Max. wireless slots per monitor 16 the maximum number of test subject that can be connected
Internal RAM 4000 MB minimum PC internal memory
HL7 compatible
HL7 compatible
Microsoft Windows 10
compatible with Microsoft Windows 10
Microsoft Windows 8
compatible with Microsoft Windows 8
Microsoft Windows 7
compatible with Microsoft Windows 7
Infopath compatible
Infopath compatible
PC included
the software is preinstalled on a PC that is included
PC software included
software needed for operation included
Windows 10 installed
operating system preinstalled on PC
Keyboard and mouse included
Input devices are included with the PC
2 LCD screens included
2 large displays for monitoring patients
All cables included
cables for installing the complete setup are included
Bluetooth hub included
the hub needed to connect the ECG monitors is included
*Specifications are subject to change without notice.

Science

FAQ

Yes the Valiant Treadmill can be controlled by LCRM. The treadmill is supplied with a RS232 port and can be controlled by a seperate com port.
Yes the SpO2 results are visible during the rehab session.
Yes! It is very easy to create a comfortable rehab setting with Lode rehab products by looping the ergometers:

The first Lode rehab ergometer can be connected to the PC with LCRM with a Lode proprietary network to PC cable (#930930).
The second product up till the last product can be connected to the previous one, a bus network configuration.

The last product always needs a termination plug to avoid interference and loss of data. All Lode rehab products come standard with such a termination plug.

Benefits
- Flawless data connection
- High bandwidth
- No interference of COM ports
- Looping
- Full access of all data in the product to LCRM
Besides charging the device with the USB charge cable (950792), there is a docking station (950840, optional) to charge four streamers at the same time. The red light indicates the state of the battery charging. This light is on during charging and off when charging finished.
It's essential to use ECG electrodes which are suitable for stress testing. These electrodes have extra-strong adhesion and therefore stick better during exercise and/or testing. Use always 4 electrodes of the same brand, type and expiration date. The cheaper quality ECG electrodes for taking an ECG during rest will not stick enough when the patient starts to sweat.
SpO2 can be used to control the load of the ergometer. In the tab "SpO2 " you can choose to use SpO2 for automatic load adjustment and you can edit the settings (see manual LCRM 950902)
LCRM is not compatible with bicycle ergometers and treadmills of another brand, the workload, speed or slope can not be crontrolled. It is possible however to select the "ECG-only protocol" and use the non-Lode device as a stand-alone system.
When the automatic Blood Pressure option is available on the Lode ergometer, this module is compatible with LCRM. You can program the blood pressure interval in the exercise protocols.
The stage "Heart Rate Controlled" gives you the opportunity to create a protocol to train with a certain heart rate. You can set the training duration and the target heart rate. The intensity (load or speed and inclination) will be controlled by the software in order to come to this certain heart rate as well as to keep the heart rate stable around the target. To set "The Target Heart Rate" you can choose between absolute heart rate, relative to max heart rate or Karvonen.
During a training it is possible the adjust the workload (in Watt, speed slope and target HR). You can switch from workload controlled towards HR controlled and vice versa as well.
LCRM allows for data interchange with Hospital Information Systems (HIS) via the HL7 standard. Since there are many HIS that use different interpretations and versions of HL7 connectivity may not work out of the box. For some HIS special adaptations need to be made. In the General Settings, tab HL7 you can connect to your HL7 server if you have one. Please contact your systems administrator for the settings. Lode can provide support to implement your specific communication requests. You may contact Lode if this is required.
The LCRM software is not meant to be a diagnostic tool, the ECG signal can be used for monitoring up to 16 patients simultaneously. For a maximal (CPET) exercise test, always use a diagnostic (12-lead) exercise ECG device.
Since LCRM software version 3.0, deactivate, reactivate and remove actions are logged on username, action and id number of the operator; because of privacy and GPDR regulations names and date of births are not logged. The logfiles can be found in %appdata%/lode/lcrm as AuditLod.csv.
When there is no ergometer connected to the slot, you can create "ECG Only" Protocols. These protocols are meant to monitor ECG while the participant is doing exercises without ergometer, like ball games, squats, lunges or jumps. Keep in mind the streamer needs to be in the bluetooth range of the system and extreme muscle activity of the upper body will influence the ECG quality.
A Physical Work Capacity (PWC) Protocol can be programmed for the bicycle ergometers. During a PWC protocol the workload will increase every 2 seconds with 1 watt untill the set heart rate is reached. The Workload belonging to the target heart rate is the PWC result which is dependent on the physical condition of the patient.
A Karvonen protocol can be selected. In the Karvonen protocol the formula based on maximum heart rate and resting heart rate is implemented: HR (Karvonen) = HRrest + (HRmax - HRrest) * x%. The percentage is defined by the physician depending on the physical improvement of the participant. The resting heart rate and maximum heart rate should be defined in the participant characteristics.
the LCRM database can be connected to a MS SQL Server. Data stored on the MS SQL server can be reached from another PC with installed LCRM software which is connected to this MS SQL server.
Data locally stored can't be shared, but data stored on a MS SQL server can be shared. Please note that the raw ECG data is stored on the PC on which the trainings are performed. Only marked ECG data is stored in the database and accessible from other locations.

Part number

  • 950901

Certificates

CE Certificate Monitoring Devices for Cardiac Rehabilitation
CB certificate LCRM with Corival range

LCRM Demo Software

950902 LCRM 3.1.1 demo software

Manuals

M950900 LCRM Manual ENG
M950902 LCRM Manual Dutch

Brochures

Brochure Lode Cardiac Rehab Manager 16 English
pdf
Brochure Lode Cardiac Rehab Manager 16 German
pdf
Brochure Lode Cardiac Rehab Manager 16 Spanish
pdf

Posters

Poster Lode Cardiac Rehab Manager 16 English
Poster Lode Cardiac Rehab Manager 16 German
Poster Lode Cardiac Rehab Manager 16 Spanish

Service

Part number

  • 950901