The latest design of the Corival Recumbent ergometer offers ergometry testing for test subjects up to 300 kg! Easy positioning and access is guaranteed by the electric adjustable seat and adjustable handgrips next to the seat. Moreover, the back support can be adjusted. For safety reasons, the back support can be positioned flat in CPR position in 1 step. This ergometer can be used for elderly and obese people and in rehabilitation settings.
The Corival Recumbent is a special product from our Corival range. The Corival is one of the most popular ergometers worldwide. The low start-up load of 7 Watt is unique. The Corival can be controlled easily by all known stress ECG and pulmonary devices in the world. The ergometer has an eddy current electro-magnetic braking mechanism. The biggest advantage of this system is the accuracy which is one of the most important Lode principles. With this ergometer, the stress tests performed are reliable and reproducible. The workload is adjustable in a range of 7 to 1000 watt. Moreover, the noise level is reduced to a minimum.
Torque range | 1-70 Nm | Torque range for rpm independent workload control | |
Minimum load | 7 W | the minimum load the ergometer can provide | |
Maximum peak load | 1000 W | the maximum load the ergometer can provide for a short period of time | |
Minimum load increments | 1 W | the smallest steps with which the load can be added | |
Maximum continuous load | 750 W | the maximum power the ergometer can deliver continuous | |
Hyperbolic workload control | control of workload in hyperbolic way | ||
Maximum rpm independent constant load | 150 rpm | rpm as to which constant load can be applied | |
Minimum rpm independent constant load | 30 rpm | rpm as from which constant load can be applied | |
Optional heart rate controlled workload | control the device optionally through a set heartrate | ||
Electromagnetic "eddy current" braking system | system that very accurately applies a brake to the ergometer | ||
Dynamic calibration | continuous calibration during application of workload |
Workload accuracy from 7 to 100 W | 3 W | accuracy of the ergometer between 7 and 100 Watt | |
Workload accuracy from 100 to 500 W | 3 % | accuracy of the ergometer between 100 and 500 Watt | |
Workload accuracy from 500 to 1000 W | 5 % | accuracy of the ergometer between 500 and 1000 Watt |
Seat width | 512 mm | 20.2 inch | Width of the seatpillow |
Minimum leg length user (incl. adjustable pedals) | 650 mm | 25.6 inch | leg length to fit to pedals when adjustable cranks are used (measured inseam) |
Allowed user weight | 300 kg | 661.4 lbs | maximum patient weight |
Adjustability range seat | 400 mm | 15.7 inch | seat adjustment range |
English user interface | User interface available in English language | ||
Chinese user interface | User interface available in Chinese language | ||
Croatian user interface | User interface available in croatian language | ||
Czech user interface | User interface available in Czech language | ||
Danish user interface | User interface available in Danishlanguage | ||
Dutch user interface | User interface available in Dutch language | ||
Finnish user interface | User interface available in Finnish language | ||
French user interface | User interface available in French language | ||
German user interface | User interface available in German language | ||
Greek user interface | User interface available in Greek language | ||
Hungarian user interface | User interface available in Hungarian language | ||
Italian user interface | User interface available in Italian language | ||
Japanese user interface | User interface available in language | ||
Korean user interface | User interface available in Korean language | ||
Latvian user interface | User interface available in Latvian language | ||
Lithuanian user interface | User interface available in Lithuanian language | ||
Norwegian user interface | User interface available in Norwegian language | ||
Polish user interface | User interface available in Polish language | ||
Portugese user interface | User interface available in Portugese language | ||
Romanian user interface | User interface available in romanian language | ||
Russian user interface | User interface available in Russian language | ||
Spanish user interface | User interface available in Spanish language | ||
Swedish user interface | User interface available in Swedish language | ||
Turkish user interface | User interface available in Turkish language | ||
Ukrainian user interface | User interface available in Ukrainian language | ||
Readout Distance | Readout the distance on control unit | ||
Readout RPM | Readout the actual rpm on control unit | ||
Readout Heartrate | Readout the actual heartarte on control unit | ||
Readout Time | Readout time on control unit | ||
Readout Power | Readout the actual power on control unit | ||
Terminal operation mode | operate with an external device | ||
Screen size (diagonal) | 8.9 cm | 3.5 inch | diagonal size of the display |
Touchscreen | operation by touch screen |
Lode 38K4 interface protocol | Supports communication with Lode 38K4 protocol | ||
Lode interface protocol | Supports communication according to the Lode ergometer protocol | ||
Lode WLP interface protocol | Supports communication with Lode WLP protocol | ||
Ergoline P10 interface protocol | Supports communication with Ergoline P10 protocol | ||
Ergoline P4 interface protocol | Supports communication with Ergoline P4 protocol | ||
Schiller interface protocol | Schiller-käyttöliittymäprotokolla | ||
Bosch EKG 506 DS interface protocol | Supports communication with Bosch EKG 506 DS Protokoll | ||
USB connector | connection via USB possible | ||
RS232 in connector | connection via RS232 |
Screen resolution | 320 x 240 pixels | Screen resolution | |
Product length (cm) | 183 cm | 72 inch | length of product in cm |
Product width (cm) | 79 cm | 31.1 inch | width of the product in cm |
Product height | 149 cm | 58.7 inch | height of product |
Product weight | 107 kg | 235.9 lbs | the weight of the product |
V AC | 100 - 240 V | voltage in Volt | |
Phases | 1 | phases | |
Frequency | 50/60 Hz | frequency in Herz | |
Power consumption | 160 W | power consumption in Watt | |
Power cord length | 250 cm | 98.4 inch | length of powercord including plugs |
Power cord IEC 60320 C13 with CEE 7/7 plug | European power cord and connector standard supplied with product | ||
Power cord NEMA | NEMA power cord and connector |
IEC 60601-1:2012 | the product is IEC 60601-1 edition 3.1 compliant | ||
ISO 13485:2016 compliant | Lode fulfils ISO 13485:2016 requirements | ||
ISO 9001:2015 compliant | Lode fulfills ISO 9001: 2015 requirements |
CE class Im according to MDD93/42/EEC | CE certified | ||
CE class of product with optional SpO2 | IIa | CE class of product with optional SpO2 | |
CE class of product with optional BPM | IIa | CE class of product with optional Blood Pressure Measurement | |
CB according to IECEE CB | CB certified |
Minimum operational temperature | 14 °C | minimum temperature at which the device will work within specification | |
Maximum operational temperature | 35 °C | maximum temperature at which the device will work within specification | |
Minimum operational air pressure | 80 kPa | minimum airpressure as from which the product will be operating within specification | |
Maximum operational air pressure | 106 kPa | maximum air pressure as from which the product will be operating within specification | |
Minimum operational non-condensing humidity | 30 % | minimum non-condensing humidity at which the product will operate within specification | |
Maximum operational non-condensing humidity | 90 % | maximum non-condensing humidity at which the product will operate within specification | |
Minimum storage & transport temperature | -20 °C | minimum temperature the product may be stored and transported at | |
Maximum storage & transport temperature | 60 °C | maximum temperature the product may be stored or transported at | |
Minimum air pressure storage & transport | 50 kPa | minimum air pressure the product may be stored or transported at | |
Maximum storage & transport air pressure | 106 kPa | maximum air pressure the product may be stored and transported at | |
Min. humidity storage & transport | 10 % | minimum non-condensing humidity that the product can be stored or transport at | |
Max. humidity storage & transport | 95 % | max. non-condensing humidity that the product can be stored or transported at |